Automation

Automate Chris Titus Tool With -Config and -Preset for Repeatable PC Setups

Export your selections once and apply them to every PC you set up, with the exact commands and the errors to watch for.

Illustration of a JSON configuration file feeding several identical PCs, representing automated WinUtil setups

If you set up more than a couple of PCs, clicking through the same apps and tweaks every time gets old quickly. WinUtil supports repeatable setups through two documented parameters: -Preset for the built-in presets and -Config for your own exported selections. This guide follows the official automation guide.

-Preset vs -Config: Which WinUtil Automation Option?

Both switches let Chris Titus Tool apply a selection without you clicking through the interface, but they serve different needs.

-Preset-Config
What it appliesA built-in tweak preset: Minimal, Standard or AdvancedYour own exported selection of apps, tweaks and features
Setup effortNoneBuild and export once
Includes appsNoYes, if you ticked them before exporting
Changes between releasesPreset contents can be adjusted by the projectStays as you exported it, though keys can be retired
Best forQuick, standard cleanupsTechnicians, labs and anyone with a fixed build

A good rule: if you would accept a preset as-is in the GUI, use -Preset. If you always untick or add items, export a config.

Step 1: Build Your Selection

Open WinUtil normally and tick the apps on the Install tab, the tweaks on the Tweaks tab and any features on the Config tab that you want on every machine. Take your time; this becomes your standard build.

Tips for a good base selection

  • Start from a preset, then adjust. It is faster than ticking everything by hand.
  • Only include apps that every machine in the group needs. Role-specific software belongs in a separate config.
  • Leave out hardware-dependent tweaks, such as those affecting hibernation, if your machines include both desktops and laptops.
  • Test the selection on one PC, ideally a virtual machine, before rolling it out.

Step 2: Export It

  1. Click the gear icon in the top right corner.
  2. Choose Export.
  3. Save the JSON file somewhere you can reach from other PCs, such as a USB drive or a network share.

Export also copies a launch command that uses the saved file to your clipboard. As an alternative, the documentation site has a Config Builder where you can select options in a browser and download the file.

Give the file a descriptive name before you save it, such as the role and the export date. Six months from now, "office-2026-11.json" tells you far more than "config.json". If you maintain several builds, keep them together in one folder so you always know which is current.

Step 3: Run It on Another PC

PowerShell (Admin)
& ([ScriptBlock]::Create((irm "https://christitus.com/win"))) -Config "C:\Path\To\Config.json"

Run this in an elevated PowerShell session on the target machine. The script block form is what allows WinUtil to accept parameters.

Why not the usual command?

The everyday launch command irm "https://christitus.com/win" | iex pipes the script straight into execution, so there is nowhere to add switches. Wrapping the download in [ScriptBlock]::Create() turns it into something you can call with arguments such as -Config and -Preset.

If your path contains spaces, keep the quotes around it exactly as shown. A missing quote is one of the most common reasons an automated run fails to find the file.

Using a Built-In Preset Instead

PowerShell (Admin)
& ([ScriptBlock]::Create((irm "https://christitus.com/win"))) -Preset Standard

Valid values are Standard, Minimal and Advanced. See WinUtil Presets: Standard vs Minimal vs Advanced for how they differ.

Finding Preset Keys

Every app, tweak, feature and AppX entry has a key. Hover over an entry in WinUtil to see a tooltip reading Preset key: <key>. Toggles, dropdowns and the package manager choice do not have keys. Current exports are flat JSON, with a string for one selection or an array for several.

Because the file is plain JSON, you can open it in any text editor to see exactly what it will apply. That makes reviewing a colleague's config easy: compare the keys against the tooltips in the current WinUtil release. If you edit the file by hand, validate the JSON afterwards, as a stray comma or missing bracket will stop the import. Re-exporting from the GUI is usually safer than hand-editing.

Rules From the Automation Guide

  • Use HTTPS URLs or trusted local files. Plain HTTP does not protect the file's integrity.
  • Local paths are used exactly as given; square brackets in file names are treated literally.
  • Repeating a key selects it only once.
  • Legacy exports with grouped WPFInstall, WPFTweaks, WPFToggle and WPFFeature sections still import. Retired keys are skipped with a warning.

The "Unknown selection key" Error

If a key in your file was removed or renamed in a newer WinUtil release, the whole import is rejected and PowerShell reports Unknown selection key '<key>'. Nothing is applied. To fix it, remove or replace that key, or simply re-export your configuration from the current version. Re-exporting after major releases is a good habit. The Config Builder's generated command uses the release that built its catalogue, which keeps its keys compatible.

Practical Tips for Technicians

  • Keep one config per role, for example "office", "gaming" and "lab".
  • Include Restore Point - Create in every config.
  • Version your JSON files with the WinUtil release date you exported them from.
  • Check company policy first; the FAQ notes some tweaks can conflict with Group Policy.
  • Use the gear menu's Export Environment Report (added in 26.10.07) to record each machine's state. It is a read-only JSON file and is never uploaded automatically.

Where to Store WinUtil Config Files

  • USB drive: simple and works offline, ideal for a technician's toolkit. Keep it with your Windows 11 installer.
  • Network share: convenient in an office or lab. Make sure only trusted people can edit the file.
  • HTTPS URL: handy for remote machines. Host the file somewhere you control and always use HTTPS, as the automation guide advises.

Whichever you choose, treat config files like scripts. Anyone who can change the file can change what WinUtil does to every machine that loads it.

A Repeatable New-PC Workflow

  1. Install Windows 11 and complete the initial setup.
  2. Connect to the internet and let Windows finish any first-run activity.
  3. Open PowerShell or Terminal as administrator.
  4. Run the -Config command pointing at your file.
  5. Watch the log for warnings, especially skipped or unknown keys.
  6. Restart the PC when the run completes.
  7. Spot-check a few apps and settings, then export an environment report for your records.

For Windows 11 installation media, see Rufus vs Win11 Creator: Windows 11 Bootable USB and WinUtil Win11 Creator: Build a Debloated ISO.

Troubleshooting Automated Runs

SymptomLikely causeFix
Switches are ignoredUsed irm | iex instead of the script block formUse the [ScriptBlock]::Create() command
File not foundWrong path or missing quotesCheck the path and quote it
Unknown selection keyKey retired or renamedRemove the key or re-export
Changes not appliedPowerShell not elevatedRun as administrator
Script blocked or deletedAntivirus false positiveSee our antivirus false positive guide

Test Before You Roll Out

An automated run applies everything in one go, with no chance to untick items. That is exactly why testing matters. Before using a new or updated config on real machines:

  • Use a virtual machine. A fresh Windows 11 VM shows you the result on a clean system and can be reset in minutes.
  • Check apps and tweaks separately. Confirm each app installed and opens, then review the tweaks you care about in Settings.
  • Test on one real device. Hardware-specific behaviour, such as power plans on laptops, only shows up on physical machines.
  • Record the WinUtil version. If you test with one release and deploy with a later one, retest after the upgrade.

Avoid testing configs on the development branch (/windev) unless you specifically want pre-release behaviour. Stable releases are what your machines will normally run.

Common Chris Titus Tool Automation Mistakes

  • Using one config for every machine. Laptops, desktops and shared PCs often need different tweaks.
  • Never re-exporting. Old keys eventually cause the whole import to be rejected.
  • Leaving out a restore point. Automation makes mistakes faster, so always include one.
  • Running on managed devices without permission. Some tweaks can conflict with Group Policy.
  • Not reading the log. Warnings about skipped keys appear there, and they explain why a setting was not applied.

Keeping Your Configs Up to Date

WinUtil releases frequently, and keys are occasionally renamed or retired. A config that worked months ago may be rejected today. After each major release, load your config on a test machine or open it in the GUI, then export it again from the current version. Keep the previous file too, named with its release date, so you can compare what changed. Checking the WinUtil version history before re-exporting tells you whether anything relevant to your build was added or removed.

Frequently Asked Questions

Click the gear icon in the top right, choose Export and save the JSON file. A launch command using the file is copied to your clipboard.

A key in your config was renamed or removed in a newer release. Remove it or re-export the configuration with the current version.

Yes. Use the script block command with -Preset Standard, Minimal or Advanced.

Piping into iex cannot pass parameters. Use the script block form: & ([ScriptBlock]::Create((irm "https://christitus.com/win"))) -Config "path".

The automation guide allows HTTPS URLs or trusted local files. Avoid plain HTTP, which does not protect the file's integrity.

Not every release, but re-exporting after major releases avoids Unknown selection key errors when keys are renamed or retired.

Sources

Facts in this guide were checked against these official and primary sources on November 16, 2026. WinUtil changes often, so the official documentation is the final word.